Add to Cart
AMC16Z-FDK48 monitor the full power parameters and switch state of 48 branches of double-channel DC outlet, 1-channel RS485 communication and phase adjustment.
● Designed specifically for the power supply management of server in the data center
● A+B independent 24 circuits(48 in total)
● kWh Class 0.5
● DIN 35 mm
Characteristic
![]() | ![]() | ![]() |
Communication | Multi-circuit power meter | Rated U and I |
RS485 (Modbus-RTU) | A+B independent 24 circuits (48 in total), DC12V output | AC 220/380V |
Function
* 24 channels of each circuit of A+B independent 2 circuits the outgoing * 1 RS485 communication | ![]() |
![]() | Installation: DIN rail 35mm
Dimension(L*W*H): 180*94.3*75mm |
Appearance
![]() | ![]() | ![]() |
Wiring
Typical connection
Utline Shape
Installation Diagram
Product Selection
Name | Pic | Model | Main Function |
HMI
| ![]() | ATP007kt ATP010kt | 1.7 or 10 inch touch screen 2.Real-time monitoring and display voltage,current,power,energy,power quality,switch status,waveform curve and so on. 3.monitoring device alarm,communication and other parameters can be configured on the screen. 4. 2 RS485 and 1 Ethernet interface,and data can be uploaded by RS485 or RJ45. |
AC incoming line monitoring module | ![]() | AMC16Z-ZA | 1. Installation:DIN rail 35mm 2. Measurement:A+B independent 3 phase circuits, 6DI2DO,2 leakage current,1 temp. and humidity. 3. With DC 24V output power supply for outgoing line module and touch screen. 4. Communication:RS485 Modbus RTU |
AC outgoing line monitoring module | ![]() | AMC16Z-FAK24 AMC16Z-FAK48 | 1. Installation:DIN rail 35mm 2. Can measure up to 16 circuit 3 phase or 48 circuit single phase 3. DC24V power supply 4. Communication:RS485 modbus RTU
|
AC outgoing line current transformer | ![]() | AKH-0.66W | Current ratio:100A/50mA Common Specification: 100A/50mA |
DC incoming line monitoring module | ![]() | AMC16Z-ZD | 1.Installation:DIN Rail 35mm 2.Measurement:A+B independent circuits,6DI2DO,1 temp. And humidity. 3.With DC 24V output power supply for outgoing line module and touch screen. 4.Communication:RS485 modbus RTU |
DC outgoing line monitoring module | ![]() | AMC16Z-FDK24 AMC16Z-FDK48 | 1. Installation:DIN Rail 35mm 2. Can measure up to 48 circuits DC outgoing line 3. DC24V power supply 4. Communication:RS485 modbus RTU
|
DC incoming line insulation monitoring module | ![]() | AMC16Z-ZJY | 1. Installation:DIN Rail 35mm 2. Measure A+B independent DC circuit ground insulation resistance of main bus 3. DC24V power supply 4. Communication:RS485 modbus RTU |
DC outgoing line insulation monitoring module | ![]() | AMC16Z-FJY | 1. Installation:DIN Rail 35mm 2. Measure 24 circuits ground insulation resistance of DC outgoing line |
DC outgoing line hall effect current sensor | ![]() | AHKC-BS | Current ratio:100A/5V Common Specification: 100A/5V |